弱电网下并网逆变器锁相环优化方法
DOI:
作者:
作者单位:

作者简介:

通讯作者:

中图分类号:

TH86

基金项目:

国家自然科学基金项目(52077030)资助


An optimized method of PLL for grid-connected inverter in the weak grid
Author:
Affiliation:

Fund Project:

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    针对弱电网条件下并网逆变器锁相环精度易受电网电压畸变、频率偏移、三相电压不平衡以及直流电压偏置等工况影 响的问题,本文提出一种适用于弱电网下并网逆变器的解耦双同步坐标系锁相环(DDSRF-PLL) 优化方法。 首先在建立 DDSRF-PLL 模型的基础上,从理论角度证明电网电压畸变和直流电压偏置是影响传统 DDSRF-PLL 锁相精度的关键因素;而后 利用傅里叶变换具备抗谐波和抗直流偏置干扰的优点,提出基于滑动傅里叶变换(SFT)的频率自适应鉴相器,继而构建适用于 并网逆变器的优化解耦双同步坐标系锁相环。 在电网电压发生畸变时本文所提锁相环在 20 ms 内可以完成对电压相位跟踪, 在电网电压存在直流偏置的情况下本文所提锁相环能在 10 ms 内快速跟踪电压相位,且相位超调量在 1°以内。 实验结果表明, 本文所提锁相环在弱电网环境下能快速准确的提取电网电压的频率和相位信息,有助于并网逆变器在电网电压畸变、电网电压 直流偏置和电网电压不平衡等复杂工况下降低输出电流谐波含量。

    Abstract:

    The accuracy of the phase locked loop of grid-connected inverter conditions is easily affected by grid-side voltage distortion in the weak grid, including frequency offset, three-phase voltage imbalance, and DC voltage offset. To address these issues, a decoupled double synchronous reference frame phase locked loop (DDSRF-PLL) optimization method for grid-connected inverter is proposed in this article. First, based on the formulation of the DDSRFR-PLL model, it is proved from a theoretical perspective that the grid voltage distortion and DC voltage offset are two key factors affecting the phase-lock accuracy of the conventional DDSRF-PLL. Secondly, a frequency adaptive phase discriminator based on sliding Fourier transform is proposed by using Fourier transform′s advantages of suppress harmonics and DC bias. Then, a phase locked loop suitable for grid-connected inverters is established under an improved decoupled double synchronous reference frame. When the grid voltage is distorted, the proposed PLL can re-track the voltage phase within 20 ms. In the case of a DC bias in the grid voltage, the PLL could quickly track the voltage phase within 10 ms. The phase overshoot is all within 1°. Experimental results show that the PLL can quickly and accurately extract the phase information of the grid voltage in the weak grid, which helps the grid-connected inverter to reduce harmonics of the output current under complex conditions, such as grid voltage imbalance and distortion.

    参考文献
    相似文献
    引证文献
引用本文

陈继开,祝世启,李浩茹,钟 诚.弱电网下并网逆变器锁相环优化方法[J].仪器仪表学报,2022,43(2):234-243

复制
分享
文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:
  • 最后修改日期:
  • 录用日期:
  • 在线发布日期: 2023-02-06
  • 出版日期: